Tie-Point Refinement ADS module


Quick linksDescription :: Parameters :: Parameter descriptions :: Details

Back to top

Description


From a CATALYST Professional OrthoEngine project file, the Tie-Point Refinement ADS module refines tie points (TP) in ADS imagery. Typically, you run this module after running the Tie-Point Collection and Refinement module to further refine the results, such as when the results of previous refinements were unacceptable.
Back to top

Parameters


Name Caption
Input Project Input OrthoEngine project file
Output Folder Output folder
Project Base Name Base name for output files
Send Email Email notification settings
Overwrite Results Overwrite existing results
Thin Tie Points Whether to thin tie points
Refine Tie Points Whether to refine tie points
TP Rejection Method Tie point rejection method
TP Rejection Method Thresholds Tie point rejection method thresholds
Rejection Limit Percentage Maximum percentage of TPs to eliminate per iteration
Rejection Action Remove or deactivate TPs rejected during thinning and refinement
Back to top

Parameter descriptions

Input Project

The path and file name of the OrthoEngine project file (*.prj) in which you want to refine TPs.

Output Folder

The path and name of the folder to which to write the output files.

Project Base Name

The base name to use to prepend the names of the output files. That is, the value you specify is used as a prefix for each output file.

Specifying a base name for the output files helps you identify the files (and content thereof) according to the prefix.

Send Email

If necessary, you can set up CATALYST Enterprise to send an email notification on job start and job completion.

With this check box selected, an email message is sent to each address specified in the Email Addresses box after the job starts and on completion.

You can specify one or more addresses, and each must be separated by a comma or a semi-colon. The email address of the user currently logged in displays by default.

Overwrite Results

Select this check box to overwrite the existing output files, if any exist. If this check box is left clear, and an output file exists in the relevant folder, the status of the job displays a message informing you of the existence and name of the output file. The message is also written to the event log of the job.

Thin Tie Points

Select this check box to thin the number of tie points (TP) collected.

That is, sometimes TP collection can gather too many points on each image. The distribution of the points may also be too varied. By thinning the points, you can reduce the number collected and distribute the points more consistently. Computation time is also reduced, because the detection of points requires less effort.

Refine Tie Points

Select this check box to refine the tie points collected. If this check box is left clear, you must verify and, if necessary, manually refine the tie points.

TP Rejection Method

The method used to reject tie points (TP).

Available options are:

You can specify various values for this parameter, depending on the method selected.

TP Rejection Method Thresholds

The rejection threshold values for the value selected for the Rejection Method parameter.

This parameter is defined using two values (THRESH1, THRESH2); these differ in meaning depending on the selected rejection method:

Rejection Limit Percentage

The maximum percentage of the initial number of TPs to eliminate per refinement iteration.

Rejection Action

Select whether to remove or deactivate tie points (TP) rejected during thinning and refinement.

The available options are as follows:
Back to top

Details

General job details

Preprocessing requirements

Before running this module, the following requirements must be met to ensure the job processes successfully and produces accurate results:

Module details

The Tie-Point Refinement ADS module reads the input project file, and then refines all of the TPs the file contains.

Job results

The Tie-Point Refinement ADS module produces the following output:
  • Updated OrthoEngine project file, containing the refined TPs.
You can now open the project in OrthoEngine to perform QA, or proceed to use the next module in the CATALYST Enterprise workflow. Typically, this is to run one or both of the following:
  • DEM Extraction module
  • Orthorectification ADS module

© PCI Geomatics Enterprises, Inc.®, 2026. All rights reserved.