| Environments | PYTHON :: EASI |
| Quick links | Description :: Parameters :: Parameter descriptions :: Details :: Example :: Related |
| Back to top |
| Back to top |
| Name | Type | Caption | Length | Value range |
|---|---|---|---|---|
| FILIRGB1 * | String | Primary Input RGB file name | 1 - 192 | |
| FILIRGB2 | String | Secondary Input RGB file name | 0 - 192 | |
| FILINIR | String | Input NIR file name | 0 - 192 | |
| CALRGB1 * | String | Primary RGB camera calibration file | 1 - 192 | |
| CALRGB2 | String | Secondary RGB camera calibration file | 0 - 192 | |
| CALNIR | String | NIR calibration file | 0 - 192 | |
| OPERATION | String | Operation to perform | 0 - 192 | STACK | STITCH | BOTH | AUTO Default: AUTO |
| FILO * | String | Name of output file | 1 - 192 | |
| REPORT | String | Report mode | 0 - 192 | Quick links |
| Back to top |
FILIRGB1
Primary RGB Input imagery filename. When stitching, this should be the left RGB image, when stacking without stitching, this should be the only RGB image.FILIRGB2
Secondary RGB Input imagery filename. When stitching, this should be the right RGB image, when not stitching, this parameter is not used.FILINIR
NIR Input imagery filename when stacking. When not stacking this parameter is not used.CALRGB1
Calibration file for the primary RGB sensor. The file must be Australis format, and not the typical camera calibration XML file use in other CATALYST algorithms. For more information on this file type, see the details section, below.CALRGB2
Calibration file for the secondary RGB sensor. The file must be Australis format, and not the typical camera calibration XML file use in other CATALYST algorithms. For more information on this file type, see the details section, below. This parameter is required if FILIRGB2 is specified.CALNIR
Calibration file for NIR sensor. The file must be Australis format, and not the typical camera calibration XML file use in other CATALYST algorithms. For more information on this file type, see the details section, below. This parameter is required if FILINIR is specified.OPERATION
Operation to perform on the input images. - TODO - add defaultFILO
The output file to which the combined image data will be writtenREPORT
Specifies where to direct the generated report.
Available options are:
| Back to top |
System S/N YZ000042
Camera type iXM-RS280F, Rodenstock RS-90mm/Aerial (90mm)
Camera S/N YY000066
Lens S/N 12625968
Sensor Size Pixel Size (mm)
H 10652 0.00376
V 14204 0.00376
Camera Final Final
Variable Value Std.Error
C 89.4886 0.0001 (mm)
XP 17.9269 0.0002 (mm)
YP -0.1068 0.0002 (mm)
K1 7.47512e-06 2.00137e-09
K2 -3.76240e-10 2.06237e-12
K3 -2.31736e-14 6.60533e-16
P1 -1.69225e-06 1.01079e-08
P2 -1.32952e-06 8.06997e-09
B1 -6.19477e-05 1.01986e-06
B2 3.43091e-05 9.39775e-07
The first line contains the system serial number, which is used to identify the camera system.
Following lines contain the camera type, camera serial number, and lens serial number - these serial numbers are not
required for this function and may be omitted. The function is smart enough to read the file and pull out only relevant information
The sensor size and pixel size are specified, followed by the camera calibration parameters.
| Back to top |
In this example two RGB IIQ images are stitched together and stack with an NIR image
EASI>filirgb1="rgbdata/ND_4ME_0546_0024_000025L.IIQ"
EASI>filirgb2="rgbdata/ND_4ME_0546_0024_000025R.IIQ"
EASI>filinir="nirdata/NIR_4ME_0546_0024_000025.IIQ"
EASI>calrgb1="calibration/YZ000042_Calib_LEFT.txt"
EASI>calrgb2="calibration/YZ000042_Calib_RIGHT.txt"
EASI>calnir="calibration/MN010065-NIR-Calib2-AUS.txt"
EASI>operation = "BOTH"
EASI>filo="output/combined_4ME_0546_0024_000025.pix"
EASI>r iiqcombine
© PCI Geomatics Enterprises, Inc.®, 2026. All rights reserved.